Click here to view or download the datasheet in .pdf format
| SPECIFICATIONS | |||
| ELECTRICAL | |||
| Pressure Range | Any range to suit from 0-10 to 0-500 PSI Gage, Absolute or Differential | ||
| Terminal Resistance | 50Ω to 10KΩ±10% | ||
| Independent Linearity | To ±0.5% F.S. | ||
| Repeatability | ±0.1%F.S. | ||
| Power Rating | 0.10 to 0.20 Watts | ||
| Life | To 10 million cycles, depending upon application | ||
| Tempurature Sensitivity | ±0.02%/°C | ||
| Response Time | 20 milliseconds to respond to 63% of step pressure input | ||
| MECHANICAL | |||
| Overpressure | 50% | Higher Available | |
| Case Pressure | 500 PSIA | ||
| Weight | 3 ounces | ||
| ENVIRONMENTAL | |||
| Temperature Range | -55°C to +85°C | ||
| Acceleration Error | ±0.2%/G to 20G | ||
| Pressure Media | |||
| Absolute and Differential: | Air or oil, non-corrosive | ||
| Gage: | Any media compatible with Ni-Span-C, Aluminum & Stainless Steel | ||
| TYPICAL STATIC AND DYNAMIC ERROR BANDS (Based on ±0.5% Linearity) | |||
| Pressure Range (PSI) | 0-10 to 0-15 | 0-20 to 0-100 | 0-125 to 0-500 |
| Static Error Band | ±1.8% | ±1.5% | ±1.2% |
| Dynamic Error Band | ±0.8% | ±0.8% | ±0.8% |